18 01276 408404 | www.greenwood.co.uk 01276 408404 | www.greenwood.co.uk 19 INTERMITTENT EXTRACT VENTILATION INTERMITTENT EXTRACT VENTILATION SUITABLE FOR ZONE 1 AND 2 Samika LE150 Low energy adaptive extraction for kitchens and utility rooms COMPLIES WITH SYSTEM 1 Features and benefits ø150mm axial fan kitchen and utility room applications. Ceiling mounting for Utility mode only and discharge via external wall or soffit not via the roof Wall mounted only in kitchen mode Two models with varying controls including SMART timer and humidity Greenwood CommissionSMART™ - adaptive installed performance set up at the touch of a button! Secure and robust window kit designed in conjunction with social housing landlords Soft closing anti-backdraught shutters to prevent nuisance noise when the fan is not in use (remove for ceiling applications)  Integral pullcord on all models Models, control options and key data Product code Control operation Voltage IP Performance (l/s) Sound Pressure Level dB(A)* Energy Consumption (W) Price ex. VAT (£) Utility Kitchen min max min max LE150PC Single speed with pullcord 230 X4 30 60 29 47.5 3 12.3 £127.19 LE150HT Single speed with SMART humidistat & timer 230 X4 30 60 29 47.5 3 12.0 £147.11 Ancillaries for Samika LE150 ED150 Easyfix page 48 Flexiduct page 48 EG2 page 49 GG84 page 49 EWLE150 page 50 *Sound pressure level measured @ 3 metres Physical specification All measurements in millimetres unless otherwise indicated Weight: 1.2kg Materials: White satin finish ABS Plastic Installation Wiring: Must comply with IEE Regulations Cable: Ø 2 core 1mm2 max Ø 3 core 1.5mm2 max Fuse:  3 amp normally required (when fan is supplied from a 6A lighting circuit no local fuse is required) Exhaust: Ø 150mm Electrical 220–240V~50Hz Class II specification: SELV 24DC Class III Glazing: Suitable for 4–28mm LE150 glazing hole Ø 167mm 200 120 50 200 Ø150 Performance Airflow l/s Static Pressure Pa 0 10 20 30 40 50 60 80 70 0 5 10 15 20 25 30 35 LO W ENERGY Greenwood SMART Technology Halo Range Shower Fan & Light Kit High performance ceiling fan for showers Features and benefits Ø 115mm axial flow fan which fits into Ø 125mm ducting, suitable for Ceiling mounting with discharge via external wall or soffit incorporating one 90° bend. NOT suitable for vertical duct installations via a roof tile vent or similar  Complete shower fan kit including with inline fan, ducting and light included  Basic and timer options  90° bend included for installing between joists in ceiling voids  Both light fitting and fan are IPX4 rated 12V (SELV) lamp  Chrome grille option available (HCBC) e & Light Kit (125mm) Dimensions Performance Graph Air Flow m3 /h 0 50 100 150 200 250 Static Pressure Pa 40 30 20 10 0 Surface cable entry 110 122 71 Foot 90˚Bend Elite Light Unit Shower Fan 162 Ø119 115 59 55.5 175 Ø118 87 Ø180 41.5 Ø115 Data Table Performance Sound Pressure in free air level @ 3m m3 /h-1 l.s-1 dB(A) IP Rating Operation Features HC115BBK HC115TBK H115SL 90 Weight: Material: Ceiling Fixing Hole: Dimensions Performance Graph Shower Fan: Consumption: 12V Light: Lamp: Consumption: Cabling: 2 Air Flow m3 /h 0 50 100 150 200 250 Static Pressure Pa 40 30 20 10 0 Surface cable entry 110 122 71 Foot 90˚Bend Elite Light Unit Shower Fan 162 Ø119 115 59 55.5 175 Ø118 87 Ø180 41.5 Ø115 Data Table Performance Sound Pressure in free air level @ 3m m3 /h-1 l.s-1 dB(A) IP Rating Operation Features HC115BBK HC115TBK H115SL 90 HCBC wer Fan & Light Kit 11 Weight: Material: Ceiling Fixing Hole: Dimensions Performance Graph Shower Fan: Consumption: 12V Light: Lamp: Consumption: Cabling: 2 Air Flow m3 /h 0 50 100 150 200 250 Static Pressure Pa 40 30 20 10 0 Surface cable entry 110 122 71 Foot 90˚Bend Elite Light Unit Shower Fan 162 Ø119 115 59 55.5 175 Ø118 87 Ø180 41.5 Ø115 Data Table Performance Sound Pressure in free air level @ 3m m3 /h-1 l.s-1 dB(A) IP Rating Operation Features HC115BBK HC115TBK H115SL 90 HCBC Models, control options and key data Product code Control operation Voltage IP Performance in free air Sound pressure dB(A)* Price ex. VAT (£) m3 /h l/s HC115BBK Kit comprising basic induct fan, internal grille with 12V light unit, LV light transformer, 90° bend, 3 metres of Flexiduct, 4 fixing clips, outlet grille and fixing screws. Single speed 230 X4 200 56 31 £83.67 HC115TBK Kit comprising induct fan with adjustable timer, internal grille with 12V light unit LV light transformer, 90° bend, 3 metres of Flexiduct, 4 fixing clips, outlet grille and fixing screws. Single speed 230 X4 200 56 31 £94.93 H115SL Options to replace 12V light unit, LV light transformer and 90° bend 230 X4 - - - £41.15 HCBC Chrome internal grille - - - - - £10.26 *Sound pressure level measured @ 3 metres Physical specification All measurements in millimetres unless otherwise indicated Weight: 0.92kg Materials: ABS white plastic Ceiling Fixing Hole: 145mm diameter Installation Shower Fan: 230V~50Hz class II Consumption: 20W 12V Light: 12V~50Hz class II Lamp: 12V diachronic lamp rated at 20W, 36° beam angle. GE Lighting Type: M269 Consumption: 20W (SELV) Cabling: Ø 1.5mm2 max Performance Halo Range - Shower Fan & Light Kit Halo Range Shower Fan & Light Kit (125mm) Weight: Material: Ceiling Fixing Hole: Dimensions Performance Graph Air Flow m3 /h 0 50 100 150 200 250 Static Pressure Pa 40 30 20 10 0 Surface cable entry 110 122 71 Foot 90˚Bend Elite Light Unit Shower Fan 162 Ø119 115 59 55.5 Ø118 Ø115 SUITABLE FOR ZONE 1 AND 2 2 2 2 2